Showing results: 301 - 315 of 377 items found.
-
4026 -
SPECTEC Innovative Sensor Solutions
Model 4026 Freq to Voltage or Freq to Current Converter accepts frequency input from any magnetic speed sensor, digital magnetic pickup or Hall effect zero speed sensors. Input and output configurations are field selectable. Input range is adjustable between 1100 Hz - 10 kHz or 75Hz to 1100 Hz. Output selection can be configured as 4-20mA converter, 10-50mA converter, 0-5 V FTV converter or 0-10 V FTV converter. ZERO and SPAN adjustments easily calibrate to almost any measurement range, with little interaction between the adjustments.
-
ALCL-80X -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・The least influence from the external magnetic field and noise by shielding for CT.・Compliant with IEC6099-5.・Measurement value can be kept in the our cloud server through our APP "M-Tracer".・Enabled the measurement for minimum 0.1μA resolution and harmonics current.・In addition to measured values, location registration by GPS, temperature, date and time can also be saved.INQUIRY
-
HT20 -
Rinch Industrial Co.,Limited
This instrument is convenient for operator to measure magneticinduction of DC magnetic field accurately. It is characterized by its wide range, clear display of LCD, and indefectible structure of sensor.A piece of 9V dry battery, which acts as its power supply, can servefor 4 hours continuously. Meanwhile, regulated power supply (enclosed) is available to 220VAC.
-
EM-2108 | 1.5 GHz – 10 GHz -
Electro-Metrics Corp.
The EM-2108 is a standard test fixture for evaluation of the electromagnetic shielding effectiveness (SE) of planar materials. The fixture is a section of coaxial transmission line broken to allow the insertion of planar test materials. Although ASTM D4935-10 is currently limited to an upper frequency of 1.5 GHz, the EM-2108 meets and complies fully with both the impedance and SE requirements called out in ASTM test method D4935-10 up to 10 GHz. These results are shown in Figures 1 & 2. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred.
-
IMV Corporation
The principle of Reciprocal Pendulum type Pickup is to induce voltage by reciprocal motion of the seismic mass with a coil in the magnetic field being suspended by a diaphragm or coil spring.. Because of its High Sensitivity and Advanced Linearity, it is suitable for detection of malfunction or deterioration of rotational machineries. Due to its structure, mounting should be done carefully for its direction or angle.
-
McLAREN Applied Technologies
The output of a hall effect sensor is a voltage which changes in proportion to the shaft extension. A constant voltage is required across the supply and ground wires of the sensor. The sensor consists of a Hall Effect element, and a shaft which houses a magnet. When the position of the sensor changes relative to the shaft, the change in magnetic field in the sensor results in a change in output voltage.
-
Directional Impulse Detector -
Timco Instruments, LLC
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.
-
Maurer Magnetic AG
Measuring station for reproducible and location-independent measuring results for quality assurance, eg B. for cross-company supply chainsMeasurements of residual magnetism on ferromagnetic components are no longer significantly falsified by ambient magnetic fields induced in the object passive shielding, no power consumption and maintenance-free defined measuring station, good measuring room accessibility Platform in a robust design
-
Vacuum Interrupters, Inc.
Until now, the accepted field service test for vacuum interrupters has been a simple Go/No-Go test performed with an AC high potential test. Today, testing with our Magnetic Atmospheric Condition (MAC) test sets can prevent unnecessary damage to your circuit breakers and contactors by predicting the usable life of the vacuum interrupter.
-
GM2 -
Alpha Lab, Inc.
The Model GM2 Measures the strength and polarity of magnetic field up to 30kG when using a standard probes, or 800 gauss (resolution 0.01 gauss) if an HS probe is used. Functions include DC, AC and peak hold along with a user-adjustable alarm which has three modes of operation. DC background field can be subtracted out either by pressing "Relative Zero" or by manually adjusting the offset. The meter includes battery, AC adapter analog output jack and calibration certificate. If a standard probe is used, resolution is 0.1 gauss up to 19,999.9 gauss, which is stronger than the field of any permanent magnet. This 5 digit display allows measurement of tiny difference in strong fields. Above 20kG the meter autoranges to a 30kG range.
-
W-IE-NE-R, Plein & Baus GmbH
MARATON is a family of MAgnetic field and RAdiation TOleraNt power supplies developed for CERN LHC. MARATON MHE represents a 12 channel low-voltage power supply for installation in a moderate hostile environment with integrated CANbus remote monitoring and control interface. Voltages, currents, temperatures and output power are controlled by the internal processor and illegal modes as well as failure will be detected.
-
AGILOG 2 -
Aeronautical & General Instruments Ltd.
AGILOG 2 is based on the well-established electromagnetic principle that a voltage is induced in a conductor by a moving magnetic field. By using the sea water as a conductor, an output is generated as the vessel progresses. Electromagnetic speed measurement is passive in operation and therefore particularly suitable for use in submarines and warships. The EM technology provides reliable and robust speed availability when compared to some alternative technologies.
-
480 -
Lake Shore Cryotronics, Inc.
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 Fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined. The Model 480 is valuable for magnetizing, manual and automated magnet testing and sorting, and as the main component in BH loop or hysteresis measurement system applications.
-
AOSense
AOSense is excited to offer free-space optical isolators at 780 nm and 852 nm. The innovative, small package size enables integration into compact laser sources and amplifiers without sacrificing transmission efficiency. The low external magnetic field enables the isolator to tightly integrate into systems with high magnetic-field sensitivity such as atomic spectrometers, magnetometers, clocks, and cold-atom devices.
-
ZGC -
Alpha Lab, Inc.
The model ZGC zero gauss chamber reduces the environmental magnetic field (Earth field) to near zero inside the chamber. Any gaussmeter probe which is less than 9.4 mm or 0.370" diameter can be placed inside. The meter is then "zeroed", which means that it will read zero whenever the probe is subsequently placed in zero field. By using a zero gauss chamber, any offset error is therefore eliminated. The model ZGC is unique in that it contains a degausser (demagnetizer). This is situated between the inner and outer mu-metal shields. When the degauss button is pressed, any accidental magnetization of the chamber, no matter how strong, is erased. Accidental magnetization is a major problem with most zero gauss chambers and it has limited their use. If a magnet comes too close, the chamber will become "permanently" magnetized and will have an internal field that is typically 0.2 to 0.5 gauss. The chamber must then be degaussed because the Earth field is also around 0.5 gauss, so a magnetized zero gauss chamber will not significantly reduce the field.